MILK COOLING TANK/BULK MILK COOLERS
Salient Features:
- Vertical open type tank
- Inside stands to hold milk can of different sizes
- Chilled water sprinkling system for culling
- AISI stainless steel inner and outer vessel
- Smooth inner sides, perfectly polished welding
- Fin insulation with precisely controlled infusion of high density environment friendly polyurethane foam
- Extreme efficiency of washing due to inbuilt sprinklers new design of spray jets
Utility
- Best suitable for small farmers
- Easy handling of milk cans
- No manual touch with leading to hygiene
- Transportation of chilled milk with cans
Refrigerating plant
- Direct expansion
- No freezing of milk, even at low filling
- Cost saving due to higher culling efficiency
- Performance as per class 2AII ISO 5708
Electrical
- Milk tank controller manages following function
- Milk temperature control
- Temperature digital display
- Compressor start up program
- Extra protection against uneven voltage functions
- Electrical supply-single phase 220 volts 50 hz or Three phase 415 volts+N50 hz.
Milk Tank Detail
- Designed and manufactured as per ISO 5708
- Circular and rectangular tank with AISI 304 grade SS Material
- Special evaporation with spot welding and laser welding
- Suitable for two milking
- Top cover of BMC has provided proper stiffening pipe& holes for milk inlet.
- Outlet connection with B/F Value
- SS dip Stick for measuring quantity of milk is provided
- Insulated with 40 kg. cc mtr density puff material
- Four nos leg with 50 mm level adjustment.
Condensing unit details
- Designed as per guidelines of ISO R/1662 with meets cooling requirement of B.M.C. specification In ISO 5708
- Sealed compressors of reputed make
- Air cooled condenser
- Split type design, easy to install
Agitator
- Free from vibratos and noise
- Maintain equal temperature throughout the tank.
Control Panel
- Mounting on condensing unit itself
- Can be operate auto/manual mode
- Digital temperature indicator & Controller with safety devices with data logger
Technical Specifications
SR.
NO. |
DESCRIPTION | SSI-BMC- 100 | SSI-BMC- 200 | SSI-BMC- 300 | SSI-BMC- 500 | SSI-BMC- 1000 | SSI-BMC- 2000 | SSI-BMC- 2500 | SSI-BMC- 5000 |
A. | REFRIGERATION UNIT:- | ||||||||
100 LTRS. | 200 LTRS. | 300 LTRS. | 500 LTRS. | 1000 LTRS. | 2000 liters | 2500 LTRS | 5000 liters | ||
1. | TYPE | DIRECT EXPANSION | DIRECT EXPANSION | DIRECT EXPANSION | DIRECT EXPANSION | DIRECT EXPANSION | DIRECT EXPANSION | DIRECT EXPANSION | DIRECT EXPANSION |
2. | MAKE OF COMPRESSOR | EMERSON / DANFOSS | EMERSON / DANFOSS | EMERSON / DANFOSS | EMERSON / DANFOSS | EMERSON / DANFOSS | EMERSON / DANFOSS | EMERSON / DANFOSS | EMERSON / DANFOSS |
3. | TYPE OF COMPRESSORS | RECIP / SCROLL | RECIP / SCROLL | RECIP / SCROLL | RECIP / SCROLL | RECIP / SCROLL | RECIP / SCROLL | RECIP / SCROLL | RECIP /SCROLL |
4. | NO. OF COMPRESSORS | ONE | ONE | ONE | ONE | ONE | TWO | TWO | TWO |
5. | COMPRESSOR COOLING CAPACITY | 1285 KCAL/HR | 2355 KCAL/HR | 2355 KCAL/HR | 4788 KCAL/HR | 7535 KCAL/HR | 7535 KCAL/HR | 7535 KCAL/HR | 19100 KCAL/HR |
6. | TYPE OF REFRIGERANT | R-22, 404, 407C | R-22, 404, 407C | R-22, 404, 407C | R-22, 404, 407C | R-22, 404, 407C | R-22, 404, 407C | R-22, 404, 407C | R-22, 404, 407C |
7. | NO. OF FAN | ONE | ONE | ONE | ONE | ONE | TWO | TWO | FOUR |
B. | DESIGN PARAMETER | ||||||||
CAPACITY | 100 LTRS. | 200 LTRS. | 300 LTRS. | 500 LTRS. | 1000 LTRS. | 2000LTRS. | 2500 LTRS. | 5000 LTRS. | |
1. | AMBIENT TEMP. | 38 DEG.C to 45 DEG.C | 38 DEG.C to 45 DEG.C | 38 DEG.C to 45 DEG.C | 38 DEG.C to 45 DEG.C | 38 DEG.C to 45 DEG.C | 38 DEG.C to 45 DEG.C | 38 DEG.C to 45 DEG.C | 38 DEG.C to 45 DEG.C |
2. | COOLING TIME | Less Then 3 hours & 3 hours | Less Then 3 hours & 3 hours | Less Then 3 hours & 3 hours | Less Then 3 hours & 3 hours | Less Then 3 hours & 3 hours | Less Then 3 hours & 3 hours | Less Then 3 hours & 3 hours | Less Then 3 hours & 3 hours |
3. | EVAPORATOR COOLING SURFACE AREA | More Then required | More Then required | More Then required | More Then required | More Then required | More Then required | More Then required | More Then required |
4. | MILK TEMP. RANGE | 35 DEG. TO 4 DEG. | 35 DEG. TO 4 DEG. | 35 DEG. TO 4 DEG. | 35 DEG. TO 4 DEG. | 35 DEG. TO 4 DEG. | 35 DEG. TO 4 DEG. | 35 DEG. TO 4 DEG. | 35 DEG. TO 4 DEG. |
5. | POWER REQUIREMENT | ONE PHASE | ONE PHASE | ONE PHASE | ONE PHASE/ THREE PHASE | ONE PHASE/ THREE PHASE | ONE PHASE/ THREE PHASE | ONE PHASE/ THREE PHASE | THREE PHASE |
C. | MILK TANK AISI 304 S.S. | ||||||||
CAPACITY | 100 LTRS. | 200 LTRS. | 300 LTRS. | 500 LTRS. | 1000 LTRS. | 2000 | 2500 | 5000 LTRS. | |
1. | GROSS CAPACITY | 110 LTRS. | 220 LTRS. | 330 LTRS. | 550 LTRS. | 1100 LTRS. | 2200 | 2550 | 5500 LTRS. |
2. | MATERIAL OF CONSTRUCTION | AISI S.S.304 | AISI S.S.304 | AISI S.S.304 | AISI S.S.304 | AISI S.S.304 | AISI S.S.304 | AISI S.S.304 | AISI S.S.304 |
3. | TYPE OF TANK | CIRCULAR VERTICAL | CIRCULAR VERTICAL | CIRCULAR VERTICAL | CIRCULAR VERTICAL / HORIZONTAL SEMI CYLINDRICAL | CIRCULAR VERTICAL / HORIZONTAL SEMI CYLINDRICAL | HORIZONTAL SEMI CYLINDRICAL / HORIZONTAL ELEPTICAL CLOSE | HORIZONTAL SEMI CYLINDRICAL / HORIZONTAL ELEPTICAL CLOSE | HORIZONTAL ELEPTICAL CLOSE |
4. | THICKNESS OFINNER SHEET | 1.5 MM / 2 MM | 1.5 MM / 2 MM | 1.5 MM / 2 MM | 2 MM | 2 MM | 2 MM | 2 MM | 2 MM |
5. | THICKNESS OF OUTER SHEET | 1 MM / 1.5 MM | 1 MM / 1.5 MM | 1 MM / 1.5 MM | 1.5 MM | 1.5 MM | 1.5 MM | 1.5 MM | 1.5 MM |
6. | RPM & NO. OF AGITATOR | 19-28 / ONE | 19-28 / ONE | 19-28 / ONE | 19-28 / ONE | 19-28 / ONE | 19-28 / ONE | 19-28 / ONE | 19-28 / ONE |
7. | CIP SYSTEM | MANUAL | MANUAL | MANUAL | MANUAL | MANUAL | MANUAL/SPRAY BALL | MANUAL/SPRAY BALL | SPRAY BALL |
8. | TYPE OF INSULATION | Polyurethane High Density | PolyurethaneHigh Density | Polyurethane High Density | Polyurethane High Density | Polyurethane High Density | Polyurethane High Density | Polyurethane High Density | Polyurethane High Density |
9. | THICKNESS OF INSULATION | 50 MM to 120 MM | 50 MM to 120 MM | 50 MM to 120 MM | 50 MM to 120 MM | 50 MM to 120 MM | 50 MM to 120 MM | 50 MM to 120 MM | 50 MM to 120 MM |
D. | CONNECTED LOAD: | ||||||||
CAPACITY | 100 LTRS. | 200 LTRS. | 300 LTRS. | 500 LTRS. | 1000 LTRS. | 2000 / 2500 LTRS. | 2500 LTRS. | 5000 LTRS. | |
1. | COMPRESSOR AMP./WATT | 3.1 AMP./ 685 WATT | 4.7 AMP/ 1020 WATT | 4.7 AMP/ 1020 WATT | 7.8 AMP/ 1750 WATT | 13.6 x 4.9 AMP / 2720 WATT | 6.1 AMP/ 3300 WATT | 6.1 AMP/ 3300 WATT | 13.3 AMP/ 7580 WATT |
2. | AGITATOR AMP. ON LOAD | 0.7 AMP | 0.7 AMP | 0.7 AMP | 1 to 0.7 AMP | 1 AMP | 1 AMP | 1 AMP | 1 AMP |
3. | AGITATOR AMP with OUT LOAD | 0.35 AMP / 0.1 AMP | 0.35 AMP / 0.1 AMP | 0.35 AMP / 0.1 AMP | 0.35 AMP / 0.1 AMP | 0.35 AMP / 0.1 AMP | 0.35 AMP / 0.1 AMP | 0.35 AMP / 0.1 AMP | 0.35 AMP / 0.1 AMP |
4. | FAN LOAD | 0.26 to 0.85 AMP | 0.26 to 0.85 AMP | 0.26 to 0.85 AMP | 0.26 to 0.85 AMP | 0.26 to 0.85 AMP | 0.26 to 0.85 AMP | 0.26 to 0.85 AMP | 0.26 to 0.85 AMP |
5. | RECOMMEND SERVO & D.G.SET | 3 KVA | 3 KVA | 3 KVA | 5 KVA | 7.5 KVA | 15 KVA | 15 KVA | 25 KVA |
6. | UNIT CONSUMED | ACORDING CALCULATION 1000 W CONSUM 1UNIT /HOURS |
SSI-BMC- 100 | Bulk Milk Cooler | 100 LTRS. |
SSI-BMC- 200 | Bulk Milk Cooler | 200 LTRS. |
SSI-BMC- 300 | Bulk Milk Cooler | 300 LTRS. |
SSI-BMC- 500 | Bulk Milk Cooler | 500 LTRS. |
SSI-BMC- 1000 | Bulk Milk Cooler | 1000 LTRS. |
SSI-BMC- 2000 | Bulk Milk Cooler | 2000LTRS. |
SSI-BMC- 2500 | Bulk Milk Cooler | 2500 LTRS. |
SSI-BMC- 5000 | Bulk Milk Cooler | 5000 LTRS. |